{"id":6576,"date":"2026-10-19T08:34:11","date_gmt":"2026-10-19T08:34:11","guid":{"rendered":"https:\/\/derekdemars.com\/blog\/?p=6576"},"modified":"2026-10-19T08:34:12","modified_gmt":"2026-10-19T08:34:12","slug":"commercial-light-poles-complete-guide-to-height-spacing-and-parking-lot-lighting","status":"publish","type":"post","link":"https:\/\/derekdemars.com\/blog\/commercial-light-poles-complete-guide-to-height-spacing-and-parking-lot-lighting\/","title":{"rendered":"Commercial Light Poles: Complete Guide to Height, Spacing, and Parking Lot Lighting"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Poor parking lot lighting is often a layout problem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A bright fixture cannot fix a badly planned pole system. The pole may be too short. The spacing may be too wide. The wrong optical pattern may send light outside the target area.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.ledlightexpert.com\/how-to-choose-the-right-commercial-light-pole-height-and-spacing-for-parking-lots\" target=\"_blank\" rel=\"noopener\"><strong>Commercial light poles<\/strong><\/a> must be selected with the LED fixture and site layout in mind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Height, spacing, mounting, optics, wind load, foundation design, and local requirements all matter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide explains how to plan commercial light poles for parking lots and other outdoor commercial areas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>What Are Commercial Light Poles?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Commercial light poles are structural poles used to mount outdoor lighting fixtures.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They are common at:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Shopping centers<\/li>\n\n\n\n<li>Office buildings<\/li>\n\n\n\n<li>Parking garages<\/li>\n\n\n\n<li>Parking lots<\/li>\n\n\n\n<li>Restaurants<\/li>\n\n\n\n<li>Schools<\/li>\n\n\n\n<li>Hospitals<\/li>\n\n\n\n<li>Industrial facilities<\/li>\n\n\n\n<li>Retail properties<\/li>\n\n\n\n<li>Apartment complexes<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A complete system has more than the pole.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It may include a pole shaft, base, anchor bolts, mounting arm, LED fixture, wiring, foundation, and lighting controls.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pole supports the fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fixture provides the light.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The layout determines where that light goes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These three parts must work together.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why Pole Height Matters<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pole height affects both coverage and illumination.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A taller pole can spread light over a larger area. But the fixture is also farther from the pavement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A shorter pole puts the fixture closer to the ground. It may provide strong light over a smaller area.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There is a trade-off.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The correct height depends on the size of the parking lot and the selected LED fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Other factors include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Required light levels<\/li>\n\n\n\n<li>Fixture lumen output<\/li>\n\n\n\n<li>Optical distribution<\/li>\n\n\n\n<li>Pole location<\/li>\n\n\n\n<li>Parking layout<\/li>\n\n\n\n<li>Property boundaries<\/li>\n\n\n\n<li>Local regulations<\/li>\n\n\n\n<li>Wind conditions<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Do not select pole height before selecting the lighting requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Common Commercial Light Pole Heights<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Commercial parking lots can use different pole heights.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The right height depends on the project.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>15-Foot Light Poles<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">15-foot poles can suit smaller properties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They may work well around:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Small parking lots<\/li>\n\n\n\n<li>Restaurants<\/li>\n\n\n\n<li>Small retail stores<\/li>\n\n\n\n<li>Office entrances<\/li>\n\n\n\n<li>Walkways<\/li>\n\n\n\n<li>Pedestrian areas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A shorter pole can help keep light closer to the property.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can also simplify maintenance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fixture must still provide adequate coverage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>20-Foot Light Poles<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">20-foot poles are useful for many medium-size commercial areas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They offer more coverage than shorter poles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They can work for office parking, retail properties, and other medium-size sites.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The final spacing must be confirmed with the selected fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>25-Foot Light Poles<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">25-foot poles can cover larger areas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They are often considered for larger parking lots and commercial properties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The increased mounting height can allow wider fixture spacing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But the fixture must have the correct lumen output and optical distribution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>30-Foot Light Poles<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">30-foot poles are useful for large sites.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They may be suitable for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Large parking lots<\/li>\n\n\n\n<li>Industrial properties<\/li>\n\n\n\n<li>Distribution facilities<\/li>\n\n\n\n<li>Large commercial centers<\/li>\n\n\n\n<li>Major outdoor areas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Higher poles require more attention to structural design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wind load becomes especially important.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The foundation must also be designed for the specific pole and site.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>How Far Apart Should Commercial Light Poles Be?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There is no universal spacing distance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pole spacing depends on the entire lighting system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A basic early estimate may use a multiple of pole height. A common starting range is around <strong>three to four times the mounting height<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example, a 25-foot pole could produce an initial planning range of about 75 to 100 feet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is only an estimate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It should not be used as the final installation plan.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A fixture with different optics may require different spacing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The final layout should consider:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pole height<\/li>\n\n\n\n<li>Fixture lumens<\/li>\n\n\n\n<li>Beam distribution<\/li>\n\n\n\n<li>Fixture orientation<\/li>\n\n\n\n<li>Required illumination<\/li>\n\n\n\n<li>Uniformity<\/li>\n\n\n\n<li>Parking space arrangement<\/li>\n\n\n\n<li>Drive lanes<\/li>\n\n\n\n<li>Trees<\/li>\n\n\n\n<li>Buildings<\/li>\n\n\n\n<li>Property boundaries<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A photometric plan provides a much better basis for final spacing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why Light Uniformity Matters<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A parking lot should not have extreme changes between bright and dark areas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Imagine standing directly under a very bright fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pavement looks well lit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Walk 40 feet away.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The area may suddenly become dark.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is an example of poor uniformity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Average illumination alone does not describe the quality of the lighting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uniformity shows how consistently light is distributed across the target area.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Good uniformity can improve visibility across parking spaces and driving lanes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can also reduce harsh changes between bright and dark areas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That is why adding higher-wattage fixtures is not always the right solution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The problem may be fixture spacing or optics.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Choose the Right LED Fixture<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pole and LED fixture should be selected as one system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Start with the required light level.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Then consider lumen output and optical distribution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A fixture with high lumen output is not automatically the best choice.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The light must reach the pavement where it is needed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Type III Optics<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Type III distribution is commonly used for roadway and parking applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It pushes light outward from the pole.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This can work well along drive lanes and parking areas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Type IV Optics<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Type IV distribution can work well near property edges.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It directs more light outward from the mounting location.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This can help illuminate areas beside the pole.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Type V Optics<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Type V distribution produces a more symmetrical pattern around the fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can work well for poles located inside an open parking area.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The exact performance varies by fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Always check the manufacturer&#8217;s photometric file.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Single-Head and Double-Head Poles<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The number of fixtures mounted on a pole affects coverage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A single-head pole has one fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can work along a parking lot edge or roadway.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A double-head pole has two fixtures.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fixtures can face opposite directions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This can be useful when a pole sits between two parking areas or rows.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">More fixtures do not always produce better lighting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Poor aiming can increase glare.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can also send light outside the target area.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fixture orientation should match the site plan.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pole Material and Finish<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Commercial light poles are available in different materials and finishes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Steel and aluminum are common choices.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Steel poles provide high structural strength.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aluminum poles are lighter and naturally resistant to corrosion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The best material depends on:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pole height<\/li>\n\n\n\n<li>Fixture weight<\/li>\n\n\n\n<li>Wind exposure<\/li>\n\n\n\n<li>Environmental conditions<\/li>\n\n\n\n<li>Required finish<\/li>\n\n\n\n<li>Project budget<\/li>\n\n\n\n<li>Local structural requirements<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Outdoor poles also need suitable corrosion protection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The coating or finish should match the site&#8217;s environmental conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Coastal locations may require additional corrosion considerations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Commercial Light Pole Foundations<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The foundation carries the structural load.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A common anchor-base system uses a concrete foundation with embedded anchor bolts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pole base plate attaches to these bolts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Some applications use direct-burial poles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Foundation requirements vary by site.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They depend on:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pole height<\/li>\n\n\n\n<li>Pole diameter<\/li>\n\n\n\n<li>Fixture size<\/li>\n\n\n\n<li>Wind speed<\/li>\n\n\n\n<li>Soil conditions<\/li>\n\n\n\n<li>Pole configuration<\/li>\n\n\n\n<li>Local building requirements<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Do not choose a concrete foundation size from a generic internet table.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pole manufacturer or a qualified structural engineer should provide the required foundation specifications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Light Pollution and Glare<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Outdoor commercial lighting should illuminate the property without creating unnecessary spill light.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Poorly aimed fixtures can send light toward:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nearby homes<\/li>\n\n\n\n<li>Roads<\/li>\n\n\n\n<li>Neighboring properties<\/li>\n\n\n\n<li>Drivers<\/li>\n\n\n\n<li>Upper-floor windows<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Glare is another concern.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A very bright fixture can make it harder to see darker areas nearby.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Good fixture selection helps control this problem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Shielding and the correct optical distribution can also reduce unwanted light.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Local outdoor-lighting rules should be checked before installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Common Commercial Light Pole Mistakes<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Using a Simple Spacing Formula<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A three-times-height rule can help with early planning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It cannot replace photometric calculations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Choosing the Highest Wattage<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">More wattage does not automatically mean better lighting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The optical pattern matters.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ignoring Pole Height<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A fixture designed for one mounting height may not perform well at another.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Placing Poles Too Far Apart<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Large gaps can produce dark areas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The result may be poor uniformity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ignoring Property Lines<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Light should be controlled within the intended area.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Check local requirements for light trespass.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Forgetting Maintenance<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">High-mounted fixtures require access for servicing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Plan maintenance access before installing the poles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Commercial Light Poles Planning Checklist<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before ordering commercial light poles, collect the site&#8217;s basic information.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This prevents expensive changes later.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Check:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Parking lot dimensions<\/strong><\/li>\n\n\n\n<li><strong>Pole mounting locations<\/strong><\/li>\n\n\n\n<li><strong>Required pole height<\/strong><\/li>\n\n\n\n<li><strong>Fixture wattage<\/strong><\/li>\n\n\n\n<li><strong>Fixture lumen output<\/strong><\/li>\n\n\n\n<li><strong>Optical distribution<\/strong><\/li>\n\n\n\n<li><strong>Required light levels<\/strong><\/li>\n\n\n\n<li><strong>Desired uniformity<\/strong><\/li>\n\n\n\n<li><strong>Pole material<\/strong><\/li>\n\n\n\n<li><strong>Wind requirements<\/strong><\/li>\n\n\n\n<li><strong>Foundation requirements<\/strong><\/li>\n\n\n\n<li><strong>Electrical voltage<\/strong><\/li>\n\n\n\n<li><strong>Lighting controls<\/strong><\/li>\n\n\n\n<li><strong>Local codes<\/strong><\/li>\n\n\n\n<li><strong>Maintenance access<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Conclusion<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Commercial light poles<\/strong> should never be selected by height alone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pole, LED fixture, optics, spacing, and foundation form one system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Start with the site.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Measure the parking area. Identify drive lanes and pedestrian paths. Check property boundaries. Determine the required light level.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Then select the pole height and LED fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use photometric calculations to confirm spacing and uniformity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This approach can prevent dark areas, excessive glare, unnecessary fixtures, and costly changes after installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Poor parking lot lighting is often a layout problem. A bright fixture cannot fix a badly planned pole system. The&hellip;<\/p>\n","protected":false},"author":2,"featured_media":6577,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6576","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/posts\/6576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/comments?post=6576"}],"version-history":[{"count":1,"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/posts\/6576\/revisions"}],"predecessor-version":[{"id":6578,"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/posts\/6576\/revisions\/6578"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/media\/6577"}],"wp:attachment":[{"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/media?parent=6576"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/categories?post=6576"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/derekdemars.com\/blog\/wp-json\/wp\/v2\/tags?post=6576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}